-- CISCO-ATM-DUAL-PHY-MIB.my: Cisco atm dual phy MIB file
--
-- July 1996, Steve Garcia and David Battle
--
-- Copyright (c) 1996-1998 by cisco Systems, Inc.
-- All rights reserved.
--
-- *****************************************************************CISCO-ATM-DUAL-PHY-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,
NOTIFICATION-TYPE,Counter32FROM SNMPv2-SMI
MODULE-COMPLIANCE,OBJECT-GROUPFROM SNMPv2-CONF
TruthValueFROM SNMPv2-TC
InterfaceIndexOrZeroFROM CISCO-TC
ifIndex,InterfaceIndexFROM IF-MIB
ciscoMgmt
FROM CISCO-SMI;ciscoAtmDualPhyMIB MODULE-IDENTITYLAST-UPDATED"9608300000Z"ORGANIZATION"Cisco Systems, Inc."CONTACT-INFO" Cisco Systems
Customer Service
Postal: 170 W. Tasman Drive
San Jose, CA 95134-1706
USA
Tel: +1 800 553-NETS
E-mail: cs-atm@cisco.com"DESCRIPTION"Initial version of this MIB module.
Phy definition
Throughout this document phy is used as an abbreviation
for Physical Interface. In particular it refers to a
physical ATM jack on a Catalyst 5000 ATM card. This card
can be fitted with either one or two physical jacks, only
one of which may be active at any given moment. The second
phy serves as a redundant connector to the ATM backbone.
Note, however, that for logistical reasons, each phy has
a separate ifIndex.
Support of the phy by ifTable
The dual phy entity on the c5K ATM line card is managed
using the ifTable. Specific interpretations of ifTable
for the dual phy entity are as follows.
Object Use for dual phy entity
====== =======================
ifIndex Each phy entity is represented by an ifEntry.
ifDescr Description of the phy entity.
ifType The value for the phy entity is other(1).
ifSpeed See [1].
ifPhysAddress An octet string of zero length, per [1].
ifAdminStatus See [1].
ifOperStatus See [1]. In addition, note that a phy can
be in the up state but still not be the
active phy. However, the active phy will
always be up.
ifLastChange See [1].
ifName See [1].
ifLinkUpDownTrapEnable disabled(2).
ifHighSpeed See [1].
ifConnectorPresent true(1).
References
[1] McCloghrie, K. and F. Kastenholz, Evolution of the
Interfaces Group of MIB-II, RFC 1573, Hughes LAN Systems,
FTP Software, January 1994."::={ ciscoMgmt 60}ciscoAtmDualPhyMIBObjects OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIB 1}cadpStatistics OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIBObjects 1}cadpStatTable OBJECT-TYPESYNTAXSEQUENCEOF CadpStatEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table of status information about ATM phy."::={ cadpStatistics 1}cadpStatEntry OBJECT-TYPESYNTAX CadpStatEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION
"An Atm Phy table entry, containing information about
a phy on this ATM module."INDEX{ ifIndex }::={ cadpStatTable 1}
CadpStatEntry ::=SEQUENCE{-- index is ifIndex-- status items
cadpStatLossOfSignal TruthValue,
cadpStatFarEndReceiveFailure TruthValue,
cadpStatActive TruthValue,
cadpStatSectionBIP8Errors Counter32,
cadpStatLineBIP824Errors Counter32,
cadpStatLineFEBErrors Counter32,
cadpStatPathBIP8Errors Counter32,
cadpStatPathFEBErrors Counter32,
cadpStatCorrectableHCSErrors Counter32,
cadpStatUncorrectableHCSErrors Counter32}
cadpStatLossOfSignal OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Set to true if the phy is currently experiencing a
loss of signal (LOS) from its connected port. Set to false
if the phy is not experiencing a loss of signal."::={ cadpStatEntry 1}cadpStatFarEndReceiveFailure OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Set to true if the phy is currently experiencing a far
end receive failure (FERF) with its connected port. Set to
false if the phy is not experiencing a far end receive
failure."::={ cadpStatEntry 2}cadpStatActive OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-only
STATUScurrentDESCRIPTION"Set to true when this phy is currently the active phy.
Set to false when this phy is not the currently active phy."::={ cadpStatEntry 5}cadpStatSectionBIP8Errors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The Bit Interleaved Parity 8 is an error checking code
applied for quick isolation of faults. Each bit in the
B octets is set to 1 or 0 as necessary to obtain even
parity over the previous frame. The calculated BIP-8
code for frame N is compared with the BIP-8 code extracted
from the B1 byte of frame N+1. Differences indicate that
a section level bit error has occurred.
Count of Section BIP-8 (Bit Interleaved Parity) errors
that have been detected on this phy. "::={ cadpStatEntry 6}cadpStatLineBIP824Errors OBJECT-TYPESYNTAXCounter32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The Bit Interleaved Parity 8/24 is an error checking code
based on even parity. The calculated BIP code for frame N
is compared with the BIP-8/24 code extracted from the B2
byte(s) of frame N+1. Any differences indicate that a
line layer bit error has occurred.
Count of line bit interleaved partiy (BIP-8/24) errors on
this phy. "::={ cadpStatEntry 7}cadpStatLineFEBErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of bits (binary 000 to 1000) in the previous
BIP-8 that didn't match the even parity check are inserted
by the transmitter. The receiver checks for this in the
M0/M1 byte of the frame. A non-zero value (legal range
is binary 0000 - 1000) indicates a line layer error in
the remote end. Any other value is treated as no error.
Count of Line Far End Bit Errors (FEBE) on this phy."
::={ cadpStatEntry 8}cadpStatPathBIP8Errors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The Bit Interleaved Parity 8 is an error checking code
applied for quick isolation of faults. Each bit in the
B octets is set to 1 or 0 as necessary to obtain even
parity over the previous frame.
The calculated BIP-8 code for frame N is compared with
the BIP-8 code extracted from the B3 byte of frame N+1.
Differences indicate that a Path level bit error has
occurred.
Count of Path BIP-8 (Bit Interleaved Parity) errors that
have been detected on this phy."::={ cadpStatEntry 9}cadpStatPathFEBErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of B3 errors in the previous frame inserted
by the transmitter. The receiver checks for this in the
G1 byte of the frame. A non-zero value (legal range is
binary 0000 - 1000) indicates a line layer error in
the remote end. Any other value is treated as no error.
Count of Path Far End Bit Errors (FEBE) on this phy."::={ cadpStatEntry 10}cadpStatCorrectableHCSErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The Header Checksum (HCS) is a CRC-8 calculation over
the first 4 octets of the ATM cell header. The received
HCS is verified using the polynomial x^8 + x^2 + x + 1.
The coset polynomial x^6 + x^4 + x^2 + 1, is added
(modulo 2) to the received HCS octet before comparison
with the calculated result. Cells with single bit error
in the HCS byte are corrected. Cells with more than one
bit error in the HCS byte are uncorrectable.
Count of incoming cells on this phy with single bit error
in the Header Checksum (HCS) byte"::={ cadpStatEntry 11}
cadpStatUncorrectableHCSErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The Header Checksum (HCS) is a CRC-8 calculation over
the first 4 octets of the ATM cell header. The received
HCS is verified using the polynomial x^8 + x^2 + x + 1.
The coset polynomial x^6 + x^4 + x^2 + 1, is added
(modulo 2) to the received HCS octet before comparison
with the calculated result. Cells with single bit error
in the HCS byte are corrected. Cells with more than one
bit error in the HCS byte are uncorrectable.
Count of uncorrectable Header Checksum (HCS) errors on
this phy."::={ cadpStatEntry 12}-- end of cadpStatTablecadpStatOperActivePhy OBJECT-TYPESYNTAXInterfaceIndexOrZeroMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Returns the ifIndex of the phy which is currently the
active phy. A value of 0 indicates that no phy is
currently active."::={ cadpStatistics 2}cadpStatAdminActivePhy OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Returns the ifIndex of the phy which is the preferred
active phy. A value of 0 indicates that no phy is
currently active.
Setting this object to a value different from its current
value causes the ATM module to make the indicated phy active,
and the active phy inactive.
Setting this object to its current value has no effect.
After performing the phy change, the agent will update
all phy information (including cadpStatOperActivePhy)
and send a ciscoAtmDualPhyChange trap."::={ cadpStatistics 3}ciscoAtmDualPhyMIBTrapPrefix OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIB 2}ciscoAtmDualPhyMIBTraps OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIBTrapPrefix 0}
ciscoAtmDualPhyChange NOTIFICATION-TYPEOBJECTS{ cadpStatOperActivePhy -- the new active phy, or 0}STATUScurrentDESCRIPTION"A ciscoAtmDualPhyChange trap is sent when the active phy
changes either because of a failure or because of user
intervention (setting cadpStatAdminActivePhy, for example)."::={ ciscoAtmDualPhyMIBTraps 1}-- conformance informationciscoAtmDualPhyMIBConformance OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIB 3}ciscoAtmDualPhyMIBCompliances OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIBConformance 1}ciscoAtmDualPhyMIBGroups OBJECTIDENTIFIER::={ ciscoAtmDualPhyMIBConformance 2}
-- compliance statementsciscoAtmDualPhyMIBCompliance MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities which implement
the Cisco Atm Dual Phy MIB. This MIB is mandatory for
all Cisco ATM products with multiple phy."MODULE-- this moduleMANDATORY-GROUPS{ ciscoAtmDualPhyMIBGroup }::={ ciscoAtmDualPhyMIBCompliances 1}-- units of conformanceciscoAtmDualPhyMIBGroup OBJECT-GROUPOBJECTS{
cadpStatLossOfSignal,
cadpStatFarEndReceiveFailure,
cadpStatActive,
cadpStatSectionBIP8Errors,
cadpStatLineBIP824Errors,
cadpStatLineFEBErrors,
cadpStatPathBIP8Errors,
cadpStatPathFEBErrors,
cadpStatCorrectableHCSErrors,
cadpStatUncorrectableHCSErrors,
cadpStatAdminActivePhy,
cadpStatOperActivePhy
}STATUScurrentDESCRIPTION"A collection of objects providing ATM dual phy monitoring."::={ ciscoAtmDualPhyMIBGroups 1}END